Access units AC10, AC20, AC40

Technical parameters:
- Supply voltage: 12V DC, 250mA consumption
- Communication interface: 1x Ethernet 100 Mbit
- Protocol: TCP/IP
- Sensor inputs: 2x or 4x (depending on unit type)
- Additional inputs: input for door contact, input for opening button
- Number and load capacity of relays: 1x, 2x or 4x (one relay max. 24V/1A)
- Number of users: unlimited, 20,000 (cards) with offline authentication
- Number of registrations: unlimited, 50,000 when offline
- Coverage: IP65 (in supplied wiring box)
- Operating temperature: -20°C to +50°C
- Dimensions (w x h x d): 220 x 170 x 86mm
User Parameters:
- The A10, AC20 and AC40 access control units have an integrated Ethernet interface and control for one, two or four doors.
- Real-time online transmission of access events to the PowerKey SW, including offline backup on the unit in the event of a connection failure.
- Remote door opening using the PowerKey mobile client.
- Pinless card access for couriers or visitors.
- Independent offline time switching of relays at predefined intervals.
- Permanent door opening with the first card and closing with the exit button.
- Automatic evaluation of the worker's presence at the workstation before he or she passes through the door or turnstile, allowing for more complex passage rules.
- Remote update of units to deploy customizations and features without the need for a service technician to be on call.
- The ability to monitor non-access data and statuses, such as open/closed or on/off states, or control third-party devices using built-in relays.
- DIN rail mountable, either in a wiring box or separately (e.g. in power supply boxes) on a rail or spacers.
Access unit F0205

Technical parameters:
- Supply voltage: 12V
- Current draw: 0.08A DC
- Interface: RS485
- Dimensions: 110 x 110 x 60 mm
- Insulation: IP30
- Operating temperature range: -5°C to +40°C
- Output: relay for door opening e.g. electromagnetic lock
- Input: connection of up to two sensors (contact, non-contact), door contact
- Supported software: Powerkey
- Maximum sensor distance (ASCI) 5 m
- Maximum card reader distance (wiegand) 60 m
User Parameters:
- The purpose of the control unit is to allow the door to be opened only by authorized persons based on the use of identification cards or chips.
- An overview of the movement of people (everything is stored in the internal memory of the F0205 unit)
- Permanent closing or permanent opening of doors
- Up to two sensors can be connected, it is possible to control the door both ways and monitor, for example, entry/exit to the building
- Indication of non-opening or forced opening of the door - door contact
- Communication with computer is via RS485 interface via FX1104 converter or TCP/IP converter
- The unit is able to operate temporarily without communication with the control software