Service and support

Access units AC10, AC20, AC40


Technical parameters:

  • Supply voltage: 12V DC, 250mA consumption
  • Communication interface: 1x Ethernet 100 Mbit
  • Protocol: TCP/IP
  • Sensor inputs: 2x or 4x (depending on unit type)
  • Additional inputs: input for door contact, input for opening button
  • Number and load capacity of relays: 1x, 2x or 4x (one relay max. 24V/1A)
  • Number of users: unlimited, 20,000 (cards) with offline authentication
  • Number of registrations: unlimited, 50,000 when offline
  • Coverage: IP65 (in supplied wiring box)
  • Operating temperature: -20°C to +50°C
  • Dimensions (w x h x d): 220 x 170 x 86mm

User Parameters:

  • The A10, AC20 and AC40 access control units have an integrated Ethernet interface and control for one, two or four doors.
  • Real-time online transmission of access events to the PowerKey SW, including offline backup on the unit in the event of a connection failure.
  • Remote door opening using the PowerKey mobile client.
  • Pinless card access for couriers or visitors.
  • Independent offline time switching of relays at predefined intervals.
  • Permanent door opening with the first card and closing with the exit button.
  • Automatic evaluation of the worker's presence at the workstation before he or she passes through the door or turnstile, allowing for more complex passage rules.
  • Remote update of units to deploy customizations and features without the need for a service technician to be on call.
  • The ability to monitor non-access data and statuses, such as open/closed or on/off states, or control third-party devices using built-in relays.
  • DIN rail mountable, either in a wiring box or separately (e.g. in power supply boxes) on a rail or spacers.

Access unit F0205


Technical parameters:

  • Supply voltage: 12V
  • Current draw: 0.08A DC
  • Interface: RS485
  • Dimensions: 110 x 110 x 60 mm
  • Insulation: IP30
  • Operating temperature range: -5°C to +40°C
  • Output: relay for door opening e.g. electromagnetic lock
  • Input: connection of up to two sensors (contact, non-contact), door contact
  • Supported software: Powerkey
  • Maximum sensor distance (ASCI) 5 m
  • Maximum card reader distance (wiegand) 60 m

User Parameters:

  • The purpose of the control unit is to allow the door to be opened only by authorized persons based on the use of identification cards or chips.
  • An overview of the movement of people (everything is stored in the internal memory of the F0205 unit)
  • Permanent closing or permanent opening of doors
  • Up to two sensors can be connected, it is possible to control the door both ways and monitor, for example, entry/exit to the building
  • Indication of non-opening or forced opening of the door - door contact
  • Communication with computer is via RS485 interface via FX1104 converter or TCP/IP converter
  • The unit is able to operate temporarily without communication with the control software